What are the benefits of inverter power modification? Many brands of inverter power board, driver board and motherboard can be used universally. As long as the model, volume and hardware are the same, you can get the desired power and voltage value by modifying the manufacturer parameters. You don't have to spend money to buy the same power accessories. Naturally, Save on maintenance costs, why not do it!
1, Yaskawa inverter G5-G7 power modification: enter the menu will be A01 = 4 and then return to 02-04 inside is the power data, after the change to restore the factory voltage has also changed.
2, Sanken inverter IHF-IPF-SHF series: enter the CD900 number parameter and input 365 to determine (change 2 times) and then find the CD202 into the input 365 to see the power and voltage parameters, 4-5.5 means 400V-5.5KW, Modify the voltage first and then determine the power to modify. Press OK when finished and exit.
3, Schneider inverter power modification: Schneider inverter after the motherboard is replaced, the power will alarm CFF, then press the ENT button continuously 3 times to restore the factory, the power voltage automatically matches.
4, Siemens 420-430-440 inverter power modification: after the motherboard is changed, the power-on display is normal, but many parameters are gone, then enter the menu No. 3 and change the value inside to 3 and then determine, find the P0201 parameters, and then After the value inside is changed to 0, the power is off and the power is off. You will find that the display shows --- staying for about 5 seconds to return to normal. At this point you will find all the parameters, and the power voltage is exactly matched to the machine.
5, Emerson inverter EV2000 power modification: enter the menu, find FU-000 to change the value inside to FA58, then change the code inside FU04, 11 = 7.5KW 12 = 11KW 13 = 15KW 21 = 90KW
6, Delta inverter power modification method: input in parameter 00-07 (old version 57522 new 33582) and then find the 00-02 parameter into the 2 display err, then change the value in 00-00 corresponding to the manual The power code is OK. The B series F series is the same.

Inversion DC - AC Power Supplies

IPS series DC - AC inversion power supplies are new generation of power dedicated AC Power Supplies for power system applications. It is mainly designed and manufactured according to the characteristics and requirements of power system.

This series of DC - AC power supplies can be divided into single-phase and three-phase AC power supplies according to the difference in the number of output phases. The output power of single-phase DC to AC power supplies ranges from 1KVA to 10KVA, and the output power of three-phase DC to AC power supplies ranges from 15KVA to 60KVA. The output voltage is divided into single-phase 220Vac and three-phase 380Vac with 50Hz fixed frequency output.


3u Ac Power Supply Front Panel15kva Ac Power Supply


This series of AC inversion power supplies are featured for high precision, stable output, high display resolution, low waveform distortion, etc., at the same time, it has complete protection functions and a friendly and convenient operation panel, which is suitable for high-quality and high-reliability AC equipment requirements.

Now, the inversion AC power supplies are widely used in power system communication, carrier, monitoring, relay protection and humidity lighting, and can also provide uninterrupted power for AC lubricating pumps, AC fans, and water pumps in power plants. And it is widely used in various fields such as aerospace, financial system, office automation control, medical and health, military scientific research and so on.

DC - AC Power Supplies, AC Inversion Power Supplies, Inversion AC Power Supplies, DC to AC Power Supplies, Inversion AC Power Source

Yangzhou IdealTek Electronics Co., Ltd. , https://www.idealtekpower.com