Basic analysis steps for faults in the field instrument system - Database & Sql Blog Articles

Huaqiang Square Crystal Zhen full range of original stock

The field instrument measurement parameters are generally divided into four parameters: temperature, pressure, flow, and liquid level.

According to the different measurement parameters, different field instrument faults are analyzed.

1. First of all, before analyzing the field instrument failure, it is necessary to thoroughly understand the production process, production process conditions and conditions of the relevant instrument system, understand the design scheme, design intent of the instrument system, the structure, characteristics, performance and parameter requirements of the instrument system.

2. Before analyzing and inspecting the faults of the on-site instrument system, it is necessary to understand the changes in the load and raw material parameters of the production operators, check the record curve of the faulty instruments, and conduct a comprehensive analysis to determine the cause of the instrument failure.

3. If the meter records a dead line (a line that has no change at all), or if the recorded curve is originally fluctuating, it suddenly becomes a straight line; the fault is likely to be in the instrumentation system. Because most of the current recording instruments are dcs computer systems, the sensitivity is very high, and the change of parameters can be very sensitive. At this point, you can artificially change the process parameters to see the curve changes. If it does not change, the basic conclusion is that the instrument system has a problem; if there is a normal change, it is basically determined that the instrument system has no major problems.

4. When the process parameters are changed, it is found that the recorded curve is abrupt or jumps to the maximum or minimum, and the fault at this time is also often in the instrument system.

5. Before the fault occurs, the meter recording curve has been normal. After the fluctuation, the recording curve becomes irregular or the system is difficult to control, and even the manual operation cannot be controlled. At this time, the fault may be caused by the process operating system.

6. When the DCS display meter is not normal, you can go to the site to check the indication value of the same intuitive meter. If they are very different, it is likely that the instrument system has failed.

In short, when analyzing the cause of the field instrument failure, pay special attention to the changes in the characteristics of the controlled object and the control valve, which may be the cause of the failure of the field instrument system. Therefore, we must comprehensively consider and carefully analyze the two aspects of the field instrument system and the process operating system to check the reasons.

Indoor Luminaires Led Driver

Indoor Luminaires Led Driver


We Provide a comprehensive range of IP Rated/Waterproof AC/DC LED Driver suitable for use in a range of Lighting applications, including Supermarket Lighting, Office Lighting, Medical Lighting, Transportation Lighting, Entertainment Lighting, Moving Signs, Safety & Security Lighting and Outdoor Area Lighting Applications. LED Lighting power supplies, Halogen Lighting Power Supplies & LED Drivers in constant voltage or constant current models and , IP65, IP66 or IP67 rated.
Products applicable to indoor for non-waterproof, like the panel light and downlight to used it.high efficiency and PF, Low harmonics,input voltage AC100-277V, With additional options such adjustable outputs and PWM, 1-10V, Resistive or triac dimming functions. Dimming safety and stability, SELV Safety output design.market are in North America, Europe, Australia, South Korea and other countries.


Indoor Luminaires Led Driver


What's the benefits of Fahold Driver?

  • Standard Linear Lighting
  • Cost-effective light-line solution for industry,commercial and other applications
  • Good quality of light with high lumen output to meet different requirements
  • Easy to order and install,requiring less time,reducing packaging waste and complexity
  • Flexible solution

FAQ:
Question 1:Are you a factory or a trading company?
Answer: We are a factory.
Question 2: Payment term?
Answer: 30% TT deposit + 70% TT before shipment,50% TT deposit + 50% LC balance, Flexible payment
can be negotiated.
Question 3: What's the main business of Fahold?
Answer: Fahold focused on LED controllers and dimmers from 2010. We have 28 engineers who dedicated themselves to researching and developing LED controlling and dimming system.
Question 4: What Fahold will do if we have problems after receiving your products?
Answer: Our products have been strictly inspected before shipping. Once you receive the products you are not satisfied, please feel free to contact us in time, we will do our best to solve any of your problems with our good after-sale service.



50W Led Driver,Led Driver Design,Led Driver Power

ShenZhen Fahold Electronic Limited , https://www.fahold.net