How to install external clamp ultrasonic flowmeter

Jiangsu Shunyi Instrument Engineer Reports: Mounting of External Clamp Sensors
1. Selection of installation methods
External clamp sensor installation method V method and Z method.
V method DN15mm-200mm pipe preferred V method, the two sensors installed horizontal alignment, the center line and the pipe axis can be parallel, and pay attention to the emission direction must be relative (two sensor direction inward). V method has the characteristics of convenient use and accurate measurement. For pipes with a diameter smaller than DN50mm, the installation accuracy is high. Please pay attention to the signal strength, signal quality, and transmission time ratio.
Z method DN200mm-6000mm pipe preferred Z method, in the V method can not detect the signal or signal quality is also poor when the Z method can also be used. When installing, the vertical distance between the two sensors in the direction of the tube axis is equal to the mounting distance, and the two sensors are guaranteed to be on the same axial plane, and the emission direction must be relative (the two sensors are facing inward). Since the Z method is an ultrasonic wave that is directly transmitted and received in the medium propagation, the signal has no reflection, and thus the signal strength is minimally attenuated. Therefore, Z method has the characteristics of high signal strength and reliable operation.

Shunyi Instrument is a domestic first-class instrument and meter supplier and has been focusing on the production and research of mass flowmeters for several years.

2. Enter the measurement parameters and get the installation distance
Before the start of the measurement, the flowmeter needs to be initially set. Usually, the menus No. 10-26 are set one by one (the M39 menu is available in multiple languages). After the settings are completed, the sensor installation distance can be obtained on the M25. This distance is Refers to the distance between the innermost edges of the two sensors and uses this data to mount the sensor.

Shunyi Instrument is a domestic first-class instrument and meter supplier and has been focusing on the research and development of ultrasonic flowmeters for several years.

3. Process installation point

There are two mounting points for the external clip sensor, which is divided into an upstream sensor and a downstream sensor. When dealing with the two mounting points, the processing area of ​​one mounting point and the size of the probe can be almost the same. The processing area of ​​the other mounting point should be 2, 3 times the size of the probe (centered on the mounting point) in order to debug signals. . First, clean the area outside the tube where the sensor is to be installed and remove the rust and paint. If there is a rust-proof layer, it should also be removed. It is best to grind the metallic luster with a sander and wipe off the oil and dust with a clean rag.